Energy monitoring connected to operations
EOS collects electricity data from Elhub and local energy meters, and shows consumption alongside the operation of ventilation, room control and heating.
Econex EOS is the umbrella name for the energy functions in Econex SD.
Start with EOS. Add more when you need it.
Below are common setups. They all use the same meters and operating data, so a module can be added without rebuilding what is already set up.
One building: energy monitoring
The base. Electricity data from Elhub and local energy meters in one overview for the building, with the project's energy and price settings. Consumption is shown alongside operating data from ventilation, room control and heating.
- Electricity data from Elhub
- Local energy meters
- Energy and price settings per project
- Connected to operational data from ventilation, room control and heating
Includes: The base
Econex · Energy follow-upIllustrationEnergy follow-upBuilding A · 5,000 m² GFAEOSConsumption48,210kWh−12 % vs. previous periodCost62,191kr−9 % vs. previous periodkWh/m²9.630 dPeak load182kW30 dConsumption per dayActualExpected (temperature corrected)BreakdownHeating22,177 kWhVentilation13,499 kWhLighting6,749 kWhOther5,785 kWh−12 % vs. previous periodIllustration with sample figures. Tenants: calculation and sub-metering
Sub-meters per tenant are linked to the calculation. EOS allocates the electricity cost including grid fees and taxes, and produces per-tenant reports that can be passed on to accounting.
Includes: The base + Tenant calculation
Read more about tenant billingEconex · EOS · LeietakereJanuar 2026 – Månedsrapport4/6 sendtTotalt fakturert84 320 krNettleie22 180 krLeietakere6vs. forrige md.-8%LeietakerForbrukEnergiNettleieAvgifterTotaltStatusAdvokatfirmaet Hauge380 m² – 2. etg.4 648 krSendtAdvokatfirmaet Hauge380 m² – 2. etg.2 840 kWh3 408 kr1 240 kr4 648 kr4 648 krSendtNordic Consulting AS520 m² – 3. etg.6 624 krSendtNordic Consulting AS520 m² – 3. etg.4 120 kWh4 944 kr1 680 kr6 624 kr6 624 krSendtTannlege Eriksen160 m² – 1. etg.2 496 krKlarTannlege Eriksen160 m² – 1. etg.1 480 kWh1 776 kr720 kr2 496 kr2 496 krKlarFitZone Treningssenter680 m² – U. etg.13 488 krSendtFitZone Treningssenter680 m² – U. etg.8 640 kWh10 368 kr3 120 kr13 488 kr13 488 krSendtBakgården Kafé120 m² – 1. etg.3 600 krUtkastBakgården Kafé120 m² – 1. etg.2 200 kWh2 640 kr960 kr3 600 kr3 600 krUtkastAutomatisk rapportflytData innhentetAutomatisk fra målereBeregning utførtNettleie + energi + avg.Rapport generertPDF til regnskapsavd.Sendt til regnskapAutomatisk e-postAutomasjonAutomatisk datainnhenting fra alle målereNettleie beregnet etter gjeldende tarifferElavgift og enova-avgift inkludertPDF-rapport sendes til regnskap den 5. hver md.Kreditnota ved feilberegning genereres automatiskIllustration with sample figures. Solar: own production against consumption
Inverters are linked to data points in the SD, and solar production appears in the energy overview next to the building's consumption. If the building has tenants, production can be included in the tenant calculation.
Includes: The base + Solar setup
Econex · EOS · SolenergiSolcelleproduksjon i dagProduksjon42.8kWhForbruk102.6kWhSelvforsynt38%i dagProduksjon vs. ForbrukForbrukSol06070809101112131415161718EnergiflytSolproduksjon42.8 kWh+12%
vs. i gårKjøpt fra nett68.2 kWh-24%
pga. solSolgt til nett8.4 kWh+340 kr
i dagEnergiflyt i dagSolproduksjon42.8 kWh+12%
vs. i gårKjøpt fra nett68.2 kWh-24%
pga. solSolgt til nett8.4 kWh+340 kr
i dagNetteksport i lavlastperioder gir best prisProduksjon vs. Forbruk (kWh)ForbrukSol06070809101112131415161718Topproduksjon kl. 12:00– 14.2 kWSelvforsyningsgradSelvforsyningsgrad38%Total produksjon42.8 kWhEget forbruk fra sol34.4 kWhEksportert til nett8.4 kWhEstimert månedlig besparelse12 450 krIllustration with sample figures. Room energy: consumption per room
Energy use and energy links at room level, with simulation. When room control is also in the SD, energy is seen together with temperature and comfort in the same room.
Includes: The base + Room energy
Econex · Room controlIllustrationRoom controlBuilding A · 11 roomsRunningFloor 2In band±1.5 °CDeviation2.14 · Meeting room FjordComfortTemperature21.1°CSetpoint21.0 °CHeatingCoolingCooling 20 %CO₂762 ppmGood air qualityVAV40%LightsCeilingBoardWallTime in comfort bandEOS97%last 30 daysEnergy 2.144.2kWh/m²last 30 daysIllustration with sample figures. Energy thieves and deviations
Analysis of energy thieves based on the meters and energy data. Consumption outside operating hours can be checked against the plants that are running, and followed up with Teknisk partner.
Includes: The base + Energy thieves
Econex · Energy follow-upIllustrationEnergy follow-upBuilding A · 5,000 m² GFAEOSConsumption48,210kWh−12 % vs. previous periodCost62,191kr−9 % vs. previous periodkWh/m²9.630 dPeak load182kW30 dConsumption per dayActualExpected (temperature corrected)BreakdownHeating22,177 kWhVentilation13,499 kWhLighting6,749 kWhOther5,785 kWh−12 % vs. previous periodDeviation · night consumptionTeknisk partnerNight consumption is 18% above expected for the last 3 days. AHU 360.003 runs outside operating hours.Illustration with sample figures.
More buildings, energy map and reporting
These parts have no screen view here. We are happy to show them on one of your buildings.
With the AI gateway you can ask questions across the buildings you have access to.
Read about the AI gateway- More buildings
- Each building is set up with its own meters and energy and price settings, built the same way from building to building. The buildings can then be compared with each other and with their own historical data.
- Energy map
- Shows which rooms and functions each energy meter covers. Useful when checking the meter structure, or when tracing a deviation from meter to plant.
- Reporting and export
- Energy data is exported to other systems, through export units or manually, for energy reporting and further analysis.
- Energy targets and measures
- Targets for energy use followed up over time, and the measures meant to reduce energy use collected in one place.
- Energy contracts
- The energy contracts linked to the buildings and meters, used in the price settings.
Meters over M-Bus, Modbus and pulse, plus Elhub
Main consumption is collected from Elhub once the customer has granted access. Local energy meters connect over M-Bus, Modbus or pulse output, and give detailed figures for technical plants, tenants and sub-areas of the building.
- Elhub data provides a stable basis for historical consumption and reporting.
- When energy data is viewed together with operations, it becomes easier to understand peaks, anomalies, and changes.
| Source | Used for |
|---|---|
| Elhub | Main consumption and historical electricity data for the building's metering points. |
| M-Bus | Energy meters for electricity, heat and water. |
| Modbus | Electricity meters and other technical equipment over Modbus RTU or TCP. |
| Pulse | Meters with a pulse output, wired to an input in the automation. |
| BACnet, KNX and MQTT | Metering points that already exist in BMS, room control or IoT gateways. |
See EOS on your building
We go through the building with you and show which modules add the most value.
The price depends on the building and the modules you choose.