Heating and cooling plants
Heating plant and circuits in one view
Econex gives a full overview of heat production and distribution – from heat pumps and boiler to every circuit – and points out the deviations that cost energy. Cooling systems are shown and operated in the same model.
The heating and cooling modules
From production to distribution and insight.
- 01 / 03
Heating plant
A full overview of the heating plant with heat pumps, boiler, buffer tank and energy use.
- Heat pump and electric boiler with run signal, alarm and working setpoint
- Boiler and buffer tank with temperatures
- Distribution circuits with flow, return, valve position and an energy meter per circuit
- Linked to energy monitoring to see what the heat costs
sd.econex.no/heating-plant/320IllustrationHeating plant 320Panel, actuators, alarms and control analysisIK401SD switchAutoPanel switchAutoSetpoint42.8 °CSetpoint offset2.0 °CCalculated setpoint44.8 °CAlarmOKIE401SD switchAutoPanel switchAutoSetpoint42.8 °CSetpoint offset-3.0 °CCalculated setpoint39.8 °CAlarmOKOutdoor7.3 °CSetpoint42.8 °CDrawn after the SD view of a heating plant. Values are synthetic – illustration, not measured data.
- 02 / 03
Heating circuits
Every heating circuit with flow and return temperature, valve position and outdoor compensation curve.
- Flow temperature against setpoint per circuit
- Valve position and pump status
- Outdoor compensation with night setback and weather-based start-up
sd.econex.no/heating-plant/320IllustrationHeating plant 320Panel, actuators, alarms and control analysis320.005 - Hot water preheatingSB501 opens when RT50175.9°Cis−5.0°Clower than 320.004-RT40444.8SB501 closes when RT50219.5°Cis−3.0°Clower than 320.004-RT40444.8320.006-JP401SD switchAutoPanel switchAutoOutdoor7.3 °CSetpoint29.8 °CDrawn after the SD view of a heating plant. Values are synthetic – illustration, not measured data.
- 03 / 03
Heating insight
Econex links heat production and distribution with energy data, and points out deviations such as high return temperatures or unnecessary boiler starts.
- Heat energy per day, week and year
- Output and energy per heating circuit over time
- Deviations shown with an explanation and suggested action
- Linked to energy monitoring in Econex EOS
sd.econex.no/heating-plant/320IllustrationHeating plant 320Panel, actuators, alarms and control analysis320.005 - Hot water preheatingSB501 opens when RT50175.9°Cis−5.0°Clower than 320.004-RT40444.8SB501 closes when RT50219.5°Cis−3.0°Clower than 320.004-RT40444.8320.006-JP401SD switchAutoPanel switchAutoOutdoor7.3 °CSetpoint29.8 °CEnergy per circuit todayOE501 energy metersEOS320.00217 kWh320.00379 kWh320.00412 kWh320.0052 kWh320.00638 kWhDrawn after the SD view of a heating plant. Values are synthetic – illustration, not measured data.
Drawn after the SD view of a heating plant. Values are synthetic – illustration, not measured data.