Ventilation
From the air handling unit to every damper
Econex brings the ventilation system into one view – air handling units, VAV and dampers, rooms and air quality. Add optimisation, commissioning, special extract and common extract when the building needs them.
The ventilation modules
Browse the modules and see what they look like in Econex.
- 01 / 07
Air handling unit
A technical view of every air handling unit with a flow diagram, temperatures along the airflow, fan performance and heat recovery.
- Supply and extract with temperatures, pressure and fan speed
- Heat recovery efficiency and SFP in real time
- Filter condition, alarms and maintenance status
sd.econex.no/building-a/ventilationIllustrationVentilationBuilding A · 3 air handling unitsRunningAir handling unitsUnit Status Dampers Alarms Supply Extract Imbalance Temp Pressure SFP 360.001Office wing Auto 42 0 8,420 m³/h 8,173 m³/h 2.9 % 19.0 °C 121 Pa 1.74 360.002Canteen/meeting Auto 18 0 3,155 m³/h 2,928 m³/h 7.2 % 19.5 °C 110 Pa 1.68 360.003Garage/storage Auto 6 0 1,885 m³/h 1,857 m³/h 1.5 % 17.0 °C 90 Pa 1.52 360.001 · Air handling unitSFP 1.74121 PaVAV dampers · 360.0012.01 Office east46%2.02 Office west52%2.03 Meeting room61%2.04 Canteen38%2.05 Office north49%2.06 Storage22%2.07 Changing room31%2.08 Reception43%Special extractSA-01Kitchen spot extract1,243m³/hRunningSA-02Waste room426m³/hRunningSA-03Lab spot extract0m³/hStandbySA-04Garage CO964m³/hDemand - 02 / 07
VAV and dampers
Every damper is linked to the room it serves and the unit it belongs to, with measured airflow against the designed vmin and vmax.
- Damper position, control signal and airflow per damper
- Vmin, vmax and nominal airflow from the design
- Alert when a damper is fully open without reaching its airflow
sd.econex.no/building-a/ventilationIllustrationVentilationBuilding A · 3 air handling unitsRunningAir handling unitsUnit Status Dampers Alarms Supply Extract Imbalance Temp Pressure SFP 360.001Office wing Auto 42 0 8,420 m³/h 8,173 m³/h 2.9 % 19.0 °C 121 Pa 1.74 360.002Canteen/meeting Auto 18 0 3,155 m³/h 2,928 m³/h 7.2 % 19.5 °C 110 Pa 1.68 360.003Garage/storage Auto 6 0 1,885 m³/h 1,857 m³/h 1.5 % 17.0 °C 90 Pa 1.52 360.001 · Air handling unitSFP 1.74121 PaVAV dampers · 360.0012.01 Office east46%2.02 Office west52%2.03 Meeting room61%2.04 Canteen38%2.05 Office north49%2.06 Storage22%2.07 Changing room31%2.08 Reception43%Special extractSA-01Kitchen spot extract1,243m³/hRunningSA-02Waste room426m³/hRunningSA-03Lab spot extract0m³/hStandbySA-04Garage CO964m³/hDemand - 03 / 07
Ventilation optimisation
The optimisation follows damper positions, air quality and comfort – not just pressure. Dampers that keep asking for more air than they can deliver are taken out of control, so the rest of the system is not pushed to needlessly high pressure.
- Pressure is built carefully when reserve is needed – not blindly
- Visible which dampers are in or out of control, and why
- SFP is shown in real time on the units where the optimisation runs
sd.econex.no/building-a/ventilationIllustrationVentilationBuilding A · 3 air handling unitsRunningOptimizerAir handling unitsUnit Status Dampers Alarms Supply Extract Imbalance Temp Pressure SFP 360.001Office wing Auto 42 0 8,420 m³/h 8,173 m³/h 2.9 % 19.0 °C 121 Pa 1.74 360.002Canteen/meeting Auto 18 0 3,155 m³/h 2,928 m³/h 7.2 % 19.5 °C 110 Pa 1.68 360.003Garage/storage Auto 6 0 1,885 m³/h 1,857 m³/h 1.5 % 17.0 °C 90 Pa 1.52 360.001 · Air handling unitSFP 1.74121 PaVAV dampers · 360.001Optimizer2.01 Office east46%2.02 Office west52%2.03 Meeting room61%2.04 Canteen38%2.05 Office north49%2.06 Storage22%2.07 Changing room31%2.08 Reception43%Special extractSA-01Kitchen spot extract1,243m³/hRunningSA-02Waste room426m³/hRunningSA-03Lab spot extract0m³/hStandbySA-04Garage CO964m³/hDemandPressure optimisationDuct pressure is lowered until the most open damper sits at ~90%. 360.001 now 121 Pa. - 04 / 07
Commissioning
With Econex as technical partner, the ventilation contractor can use Econex actively during balancing and commissioning – with a shared view of supply, extract and balance.
- Designed versus measured airflow per damper
- Imbalance between supply and extract per unit, floor and room
- Progress can be followed along the way – not just at the end
sd.econex.no/building-a/ventilationIllustrationVentilationBuilding A · 3 air handling unitsRunningAir handling unitsUnit Status Dampers Alarms Supply Extract Imbalance Temp Pressure SFP 360.001Office wing Auto 42 0 8,420 m³/h 8,173 m³/h 2.9 % 19.0 °C 121 Pa 1.74 360.002Canteen/meeting Auto 18 0 3,155 m³/h 2,928 m³/h 7.2 % 19.5 °C 110 Pa 1.68 360.003Garage/storage Auto 6 0 1,885 m³/h 1,857 m³/h 1.5 % 17.0 °C 90 Pa 1.52 360.001 · Air handling unitSFP 1.74121 PaVAV dampers · 360.0012.01 Office east46%2.02 Office west52%2.03 Meeting room61%2.04 Canteen38%2.05 Office north49%2.06 Storage22%2.07 Changing room31%2.08 Reception43%Special extractSA-01Kitchen spot extract1,243m³/hRunningSA-02Waste room426m³/hRunningSA-03Lab spot extract0m³/hStandbySA-04Garage CO964m³/hDemand - 05 / 07
Special extract
Extract for rooms with special needs – such as wet rooms, labs or kitchens. A trigger selects a low or high state, and each state has its own fan command and damper actions.
- Triggers: room switch, binary signal, humidity or AHU operation
- Dampers set to closed, Vmin, Vmax or auto per state
- Supervision of run feedback, fan fault and airflow deviation
sd.econex.no/building-a/ventilationIllustrationVentilationBuilding A · 3 air handling unitsRunningAir handling unitsUnit Status Dampers Alarms Supply Extract Imbalance Temp Pressure SFP 360.001Office wing Auto 42 0 8,420 m³/h 8,173 m³/h 2.9 % 19.0 °C 121 Pa 1.74 360.002Canteen/meeting Auto 18 0 3,155 m³/h 2,928 m³/h 7.2 % 19.5 °C 110 Pa 1.68 360.003Garage/storage Auto 6 0 1,885 m³/h 1,857 m³/h 1.5 % 17.0 °C 90 Pa 1.52 360.001 · Air handling unitSFP 1.74121 PaVAV dampers · 360.0012.01 Office east46%2.02 Office west52%2.03 Meeting room61%2.04 Canteen38%2.05 Office north49%2.06 Storage22%2.07 Changing room31%2.08 Reception43%Special extractSA-01Kitchen spot extract1,243m³/hRunningSA-02Waste room426m³/hRunningSA-03Lab spot extract0m³/hStandbySA-04Garage CO964m³/hDemand - 06 / 07
Common extract
When several rooms share an extract, Econex controls the extract dampers as one group. The required extract is calculated from the supply air, with an offset and minus fixed CAV extracts, and the remainder is shared between the controlled dampers by nominal capacity.
- Measured against the required total extract for the group
- Control signals within each damper's min and max limits, with a dead band
- Visible which dampers are in the control loop, and what the next calculated step is
sd.econex.no/building-a/ventilationIllustrationVentilationBuilding A · 3 air handling unitsRunningAir handling unitsUnit Status Dampers Alarms Supply Extract Imbalance Temp Pressure SFP 360.001Office wing Auto 42 0 8,420 m³/h 8,173 m³/h 2.9 % 19.0 °C 121 Pa 1.74 360.002Canteen/meeting Auto 18 0 3,155 m³/h 2,928 m³/h 7.2 % 19.5 °C 110 Pa 1.68 360.003Garage/storage Auto 6 0 1,885 m³/h 1,857 m³/h 1.5 % 17.0 °C 90 Pa 1.52 360.001 · Air handling unitSFP 1.74121 PaVAV dampers · 360.0012.01 Office east46%2.02 Office west52%2.03 Meeting room61%2.04 Canteen38%2.05 Office north49%2.06 Storage22%2.07 Changing room31%2.08 Reception43%Special extractSA-01Kitchen spot extract1,243m³/hRunningSA-02Waste room426m³/hRunningSA-03Lab spot extract0m³/hStandbySA-04Garage CO964m³/hDemand - 07 / 07
Fire dampers
The fire dampers in the ventilation system are monitored in the fire damper central: end positions, faults and motor tests, with a weekly test that waits until the linked air handling unit has stopped.
- Open and closed position for every damper, also on the drawing
- Weekly test that is blocked while the unit runs
- Test log with travel time and result
sd.econex.no/building-a/fire-dampersIllustrationFire damper controlBuilding A · 10 dampers · 2 AHUsAutoOpen10Closed0Faults0Test due0Next weekly test · 576.001-KA002Today at 07:10 · blocked automatically while AHU 360.001 is running.Damper register10 · polled every 5 min- OpenAutoPassed · 7 d576.001-KA001Supply technical room · FC 1-1
- OpenAutoPassed · 7 d576.001-KA002Supply office 101 · FC 1-1
- OpenAutoPassed · 7 d576.001-KA003Supply meeting room 102 · FC 1-2
- OpenAutoPassed · 7 d576.001-KA004Extract office 105 · FC 1-3
| Unit | Status | Dampers | Alarms | Supply | Extract | Imbalance | Temp | Pressure | SFP |
|---|---|---|---|---|---|---|---|---|---|
| 360.001Office wing | Auto | 42 | 0 | 8,420 m³/h | 8,173 m³/h | 2.9 % | 19.0 °C | 121 Pa | 1.74 |
| 360.002Canteen/meeting | Auto | 18 | 0 | 3,155 m³/h | 2,928 m³/h | 7.2 % | 19.5 °C | 110 Pa | 1.68 |
| 360.003Garage/storage | Auto | 6 | 0 | 1,885 m³/h | 1,857 m³/h | 1.5 % | 17.0 °C | 90 Pa | 1.52 |
Go deeper
Some modules have their own pages with more detail, articles and examples.
Ready for an operations partner that actually acts?
Contact us for a no-obligation conversation about how Econex can take action in your building – not just show you graphs.